45230678
tender for providing of otm accn for sata bty at mil stn bhuj (phase one of two phases) 1 lump sum price worked out by the contractor for building worksas listed in schedule ‘a’ part i representing percentage (+ or denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 28 2 lump sum price worked out by the contractor for site clearance, excavation & earth workas listed in schedule ‘a’ part ii representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the mes b/f from sl page no. 30 3 lump sum price worked out by the contractor for internal water supply as listed in schedule ‘a’ part iii representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 31 4 lump sum price worked out by the contractor for internal electrificationas listed in schedule ‘a’ part iv representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 36 5 lump sum price worked out by the contractor for road & foot path as listed in schedule ‘a’ part v representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 40 6 lump sum price worked out by the contractor for sewage disposalas listed in schedule ‘a’ part vi representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 42 7 lump sum price worked out by the contractor for area drainageas listed in schedule ‘a’ part vii representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the mes b/f from sl page no. 43 8 lump sum price worked out by the contractor for compound, retaining & toewall, chain link fencing & gateas listed in schedule ‘a’ part viii representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 47 9 lump sum price worked out by the contractor for external water supplyas listed in schedule ‘a’ part ix representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 48 10 lump sum price worked out by the contractor for external electrificationas listed in schedule ‘a’ part x representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 51 11 lump sum price worked out by the contractor for lighting protectionas listed in schedule ‘a’ part xi representing percentage ( + or denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the mes b/f from sl page no. 52 12 sch a part xii (miscellaneous items) notes: (i) this schedule is not pre priced by mes and the pre priced rate indicated as rs 0.00 under column 5 signifies this fact only. (ii) excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. 13 internal water supply s&f 15 mm bore, fancy type, cp brass bib cock screwed for iron pipe or cpvc pipes or for brass ferrule and fixed complete all as specified and directed.make jaquar queen series cat no qqt 7037 or techno commercial equivalent of any make specified in appx b. 14 s&f 15 mm bore, fancy type, cp brass angular stop cock screwed for iron pipe or cpvc pipes or for brass ferrule and fixed complete all as specified and directed.make jaquar queen series cat no qqt 7053 or techno commercial equivalent makes as per appx b. 15 s&f of cp wall mixer 3 in 1 system including 1.5 mtr long tele shower and overhead shower of size 150x150 mm with wall flange isi marked complete all as specified and directed.make jaquar queen series cat no 7281 or techno commercial equivalent of any make specified in appx b. 16 s& f overhead shower 150 x 150 mm of abs body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and directed.make jaquar queen series cat no 35495 or techno commercial equivalent makes as per appx b. 17 s&f health foucet with 1200 mm long flexible mild steel tube 80 mm dia with wall hook complete all as specified and directed.make jaquar queen series cat no ald 573 or techno commercial equivalent of any make specified in appx b. 18 s&f two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed.make jaquar queen series or techno commercial equivalent of any make specified in appx b. 19 s&f 15 mm bore, fancy type, cp brass bib cock screwed for iron pipe or cpvc pipes or for brass ferrule and fixed complete all as specified and directed.make jaquar essco series or techno commercial equivalent of any make specified in appx b. 20 s&f 15 mm bore, fancy type, cp brass angular stop cock screwed for iron pipe or cpvc pipes or for brass ferrule and fixed complete all as specified and directed.make jaquar essco series or techno commercial equivalent of any make specified in appx b. 21 s&f health foucet with 1000 mm long flexible mild steel tube 15 mm dia with wall hook complete all as specified and directed.make jaquar essco series or techno commercial equivalent of any make specified in appx b. 22 s&f overhead shower 114 x 114 mm of square of abs body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and directed.make jaquar essco series or techno commercial equivalent of any make specified in appx b. 23 s&f two way angle cock chromium plated fancy type 15 mm borecomplete all as specified and directed.make jaquar essco series or techno commercial equivalent of any make specified in appx b. 24 internal electrifications&f t.v./ telephone socket outlet, including m.s. box of size 100x100x65 mm with cover plate complete all as specified and directed 25 supply and fixing rj 11 gang with shutter (telephone jack) complete with all accessories complete all as specified and as directed. 26 supply and fix modular metal flush box 1/2 modulefor telephone and tv points complete all as specified and as directed. 27 supply and fix modular white cover plate with frame 1 modulefor telephone and tv points complete all as specified and as directed. 28 supply & fixpvc metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long complete all as specified and as directed. 29 s & f led light fitting 1 x 9 watt/ 1 x 10 watt bulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 30 supply & fix led lampb22 base 10 watt, min lumen output 950 lumens at 6500 k cct for batten holders complete all as specified and as directed. 31 supply & fix 12 watt led downlight having luminous efficacy of > 100, input voltage range 140 270 v, input frequency 50 60 hzcomplete all as specified and as directed. 32 m & l for drawing 12 pair / multi core coated copper telephone cable including pvc conduit of size 20mm complete all as specified and as directed. 33 m & l earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etcas required 4mm dia gi wire complete all as specified and as directed. 34 supplying, installation , testing and commissioning load line distribution board tpn vertical, 4 way double door type, fixed on wall semi flush with incoming mccb 4 poles 125 amps, 16 ka, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed.note: outgoing mcbs shall be measured and paid separately 35 s&f exhaust fan of 250 mm sweep made of sturdy engineering plastic suitable for sp 230/250 volt, 50 hz, rpm 1200 complete with louvers shutters including fixing/grouting of frame in wall and cutting opening complete and connecting with and including connecting up with three core twisted flexible copper conductor cable of 1.0 sqmm size cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed. 36 s&f exhaust fan of 300 mm sweep made of steel body suitable for sp 230/250 volt, 50 hz, rpm 1200 complete with louvers shutters including fixing/grouting of frame in wall and cutting opening complete and connecting with and including connecting up with three core twisted flexible copper conductor cable of 1.0 sq mm size cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed. 37 s&f led security light fitting 1x35 watt made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power leds inbuilt electronic driver up to 10 kv surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry cct3000 6000 cri greater than 70, input power 35 watt system with 100 lumens per watt output operating voltage 160 260v with connection by three core pvc insulated multistaranded copper conductor sheathed cable of size 1.0 sqmm fixed with & including bracket made of gi pipe 25 mm bore light grade, 1.20 m long bent to shape required with 2 nos ms clamps of suitable size and length, nuts & bolts complete all as specified and as directed. 38 road & foot pathm&l for 150 mm thick wmm (wet mix macadam) (compacted thickness) laid in two layers of 75mm thick each conforming to grading given in table 400 13 & physical requirement given in table 400 12 spread by mechanical means & rolled by using 8 10 ton vibrator power roller over compacted sub grade surface of soling as specified in clause 406 3.5 of morth specification and necessary lateral support and formwork if required complete all as specified and directed. 39 m&l for approved earth filling obtained from outside defence land, laid in layers n.exc 15 cm thick, spread, levelled including watering all as directed complete all as specified and directed. 40 compound wall, chain link fencing & gates&f cast iron (ci) wheel as rollers of 75 mm dia for gates complete. 41 m&l forprecast reinforced cement concrete (1:2:4) type b 0 using 12.5mm graded stone aggregate in louvers and jallies 45 50 mm thick (measured solid) including all mouldings but excluding frame and set in cement mortar (1:4) complete all as specified and directed. 42 external water supplysupply and lay pipe and testingductile iron both ends flanged and drilled, isi marked, class k 7, with internal cement mortar lining in nominal bore dia of 150 mm (6) dia including push on joints, alldi fittings like tee, bend ,tailpiece as per site requirement, nults and bolts complete all as specified and directed. 43 supply and lay and testingpipe ductile iron both ends flanged and drilled, isi marked, class k 7, with internal cement mortar lining in nominal bore dia of 100 mm (4) dia including push on joints,alldi fittings like tee, bend ,tailpiece as per site requiremnet, nults and bolts complete all as specified and directed. 44 supply and lay and testingpipe ductile iron both ends flanged and drilled, isi marked, class k 7, with internal cement mortar lining in nominal bore dia of 200 mm dia including push on joints,alldi fittings like tee, bend ,tailpiece as per site requiremnet, nults and bolts complete all as specified and directed. 45 supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with bronze wedge ringon both side, gland packing, class pn 1.6 with flanged ends drilled suitable for bore of pipe 100 mm isi marked (is:14846:2000) having s.s. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed. 46 supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with bronze wedge ringon both side, gland packing, class pn 1.6 with flanged ends drilled suitable for bore of pipe 150 mm isi marked (is:14846:2000) having s.s. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed. 47 supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with bronze wedge ringon both side, gland packing, class pn 1.6 with flanged ends drilled suitable for bore of pipe 200 mm isi marked (is:14846:2000) having s.s. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed. 48 m&l for cutting of existing di/ci pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessary excavaton and earthwork, dewatering etc, if any involved, complete all specified and directed for 80mm to 100mm bore of pipe complete all as specified and directed. 49 supply, install, test and commissioning cast iron flanged air valves with two air outlets, 50 mm dia bore, pn 10and fixing up in cast iron water supply mains complete all as specified and directed. 50 m&l for construction of pcc block masonary valve chamber of size 900 x900 x 900 mm (internal dimenssions) with pcc foundation 1:4:8 type d2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , one brick thick walls built in cm 1:6, 50 mm thick pcc 1:2:4 type b1 coping finished even and smooth, rendering 10 mm thick in cm (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 3 mm thick ms sheet cover fixed on 50 mm x 50 mm x 6 mm thick angle iron frame with hold fasts embedded in pcc coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. 51 external electrificationssupply, installation, testing and commisioning of stepdown transformer, outdoor type, ht 11 kv, 3 phase, lt 0.433 kv, 50 hz, 3 phase, 4 wire, oil cooled, including of first fill of transformer oil of dielectric strength not less than 50 kv, electrolyte grade, copper wound in accordance with vector group dyn 11 with neutral brought out on lv side with tapping on hv side to vary secondary voltage upto ± 7.5 % in steps of 2.5% with externally operated off load type tap changing switch, locking arrengement complete with all standard fittings, all as specified and of capacity 160 kva, level 3 mounted on a suitable platform as per manufactuers recommendation with following technical features: 52 [i] rating: hv 11 kv , lv 433 v[ii] winding connections hv delta, lv star[iii] tappings on hv: ± 2.5%, total; 7.5%, off circuit links.[iv] insulation: class h [v] applicable standards: is: 1180 (part 1 2014) [vi] termination: hv & lv cable box for easy connection.[vii] duty: distribution transformer. [viii] noise level: less than 69 db at 1 mnotes: [i] contractor shall submit the technical drawing, constructional drawings, safety features drawing etc. for approval of accepting officer.[ii] the contractor shall intimate for factory inspection for routine tests as per is & ansic57.12.90 (latest revision) in the oem factory in presence of representative nominated by the accepting officer before dispatch from factory, tests after installation shall also be carried by sei for which ge will intimate through proper channel. 53 s&f led security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power leds inbuilt electronic externaldriver up to 10 kv surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry cct 3000 6000 cri greater than 70, input power 35 w system with 100 lumens per watt output operating voltage 160 260v with connection by three core pvc insulated multistranded copper conductor sheathed cable of size 1.0 sqmm fixed with complete all as specified and as directed 54 supply and fix weather proof pvc junction box made out of not less than 2 mm thick of size 250 x 200 x 100 mm (approx) complete with hinged door locking arrangement and consisting of 01 no panel mounted connector 4 pole 32 amps 01nomcb sp 06 amps 10 ka 01 no incl 02 nos cable glands suitable for inserting cable not less than 50 sqmm with 02 no 01 mm gi plate (150 x 50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to ip 65 complete including fixing on street light pole with ms clamps, bolts, nuts and washers complete all as specified and as directed 55 supply, installation, testing and commissioning of 11 kv 200 amps triple pole gang operated air break switch having 12 nos frp insulator with earthing switch rotating type for horizontal or vertical operation mechanically operated 3 rows type mounted on frpinsulators (including insulators) and steel frame with operating mechanism consisting of operating rod of 25mm bore medium grade gi pipe of suitable length to operated from ground level including locking arrengment with pad lock with three nos of keys including 11 kv swing out expulsion fuses (drop out type) of 10 amps complete all as specified and as directed. 56 supply, install, testing and commissioning lightening arrestor (station type) outdoor nominall discharge current 65 ka, 11 kv including clamps, nuts, bolts and washers and connecting to earth with 32 x 6 mm gi strip complete all as specified and as directed. 57 supply, installation, commissioning and testing of company make automatic power factor correction (apfc) panel for 3 phase, 415 volt & 50 hz system of capacity 80 kvar in 8 steps ( 2×5 (fixed) + 4 x 12.5 + 4 x 5 kvar ) complete with relays, capacitor banks for automatic operation to power factor above 0.95. the panel should be complete with followings: 58 tp air break contacts of capacitor contacts of duty with suitable switchgear, mpp heavy duty shunt capacitor impregnated, having rated voltage of 440 v type with internal electrical switch gear each element as per is 13340 1993/is 13341 1992, iec 60831 part i & 2 of outdoor type double door (kiosk type) complete with interconnections with suitable size of copper wiring, pvc insulated unarmored cable and pvc sheath etc as required. the panel shall be made out of 3.15mm thick crca sheet powder coated with angle frame of size 50 x 50 x 6 mm cubical type including interconnection wiring, indicating lamps etc confirming to ip 42 specifications including grounding of panel as per electrical standards, electrical connections shall be made by using proper thimbles/lugs, cable gland complete all as specified and directed 59 incoming: (a) 160 amps 36 ka 4p mccb, tmd (o/l & s/c release ), ics = 100 % icu, positive isolation with stranded extended rotary handle, spreaders, 3 phase barrier, double break contacts, sealable transperant cover on trip unit 01 no (b) digital voltameter (dm3210) with primary / secondary pt programmable with selector switch 01 no (c) digital ammeter (dm3110) with primary / secondary ct programmable with selector swicth 01 no (d) led indication lamps (ryb) 01 set (e) 6 stage apfcr 01 no (f) tpn sleeved copper busbar 100a, neutral busbar shall be capacity (50 ka) 01 se 60 outgoing: (a) accessories for 5 kvar fixed compensation capacitor bank mcb, tp, 63 amp, 10 ka, d curve. (b) accessories for 12.5 kvar capacitor bank capacitor duty contactor (ac6b) 25 kvar with damping resistors which limit xinrush current, 440 volt, 3 ph, 50 hz, coil 220 lac & mcb tp 63 amp, 10 ka, d curve (b) accessories for 5 kvar capacitor bank capacitor duty contactor (ac6b) 5 kvar with damping resistors which limit xinrush current, 440 volt, 3 ph, 50 hz, coil 220 lac & mcb tp 63 amp, 10 ka, d curve note: (a) ventilating fans of required size to dissipate the heat liberated by capacitor units complete with automatic swicthing on and off of fans depending upon the temperature of panel, 230 v ac, 2650 rpm, 160 cum/h, flying leads. panel shall have silicon based fire/heat resistance coating fire retarding dmc/smc filling for the opening around the busbar near to the sectional barriers and door interlocking for all compartments 01 lot. all accessories pre wired with suitable size copper conductor cable insulated with fiber glass insulation to with stand (b) high temperature, housed in cubical panel (cpri approved) made out of 3.15 mm thick ms sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. 61 m&l for ht cable route indicator duly painted with grey colour synthetic enamel paint two coats over one coat of red oxide primer, oval shape of size 200mm x 150mm x 6mm thick cast iron disc with letters embossed and fixed on 25mmx25mmx5mm thick ms angle iron for 50mm long including necessary pcc in 1:3:6 type c1 cement concrete 20mm aggregate and 15mm thick plastering all around below ground level of size 650mm x 300mm x 250mm embedded in pcc block complete all as specified and as directed. 62 supply and fixing digital street light timer panel, outdoor type ip 54 digital programmable timer control street light auto on off ,for single or threephase load of maximum capacity 5 kw,timer panel shouldconsite of4 polemcbsof suitable 32 amp capacity, 3 polepower contactor ac 3 of3 2amps ,sp circuit break 1 nos andenclosurefor encasing above compnents complete all fixing to pole with gi strips all as specified and directed 63 boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including hdpe pipe of 150 mm dia suitable for 0.4 mps working pressure all as specified and directed 64 supply and fixing of led aviation light for die cast aluminium housing with red polycarbonate dome for illumination,integral driver,ip 65 and super flux 5mm 302 nos leds incorporated.input voltage 100 270 volts ac.life time 50000 hrs complete all as specified and directed 65 supply, installation, testing and commissioning weather and vermin proof l.t. feeder pillar boxcpri approved factory fabricated out door,double doorcubicle/kiosk typetotally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 3.0mm thick sheet metal enclosure with angle iron frame of m.s. angle 50 x 50 x 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes at bottom only with suitable pvc/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor pvc insulated cables of adequate size, duly powder coated internally/ externally of approved colour with pcc foundation andsuitable capacity copperbus bar for 3 phase & neutral mounted on epoxy insulator 01 set including connecting the following (main panel) 66 (a) copperbus bar, 600 amps , 4 pole (b) mccb 4 pole thermal magnetic release 415 volts 400 a 36 ka,ics=100%icu ,adjustable overload settings:0.8 1×in, adjustable shortcircuit settings: 6 10 × in 01 (incoming), (c) mccb 4 pole thermal magnetic release 125 amps, 16 ka,ics=100%icu ,adjustable overload settings:0.8 1 × in, adjustable shortcircuit settings: 6 10× in 02 ( lt panel 3 1 nos, 01 no for spare)(d) mccb 4 pole thermal magnetic release 63 amps, 16 ka , ics=100%icu ,adjustable overload settings:0.8 1 × in, adjustable shortcircuit settings: 6 10 × in 02 ( lt panel 1 1 nos, 01 no for spare)(e) mccb 4 pole thermal magnetic release 40 a, 16 ka, ics=100%icu ,adjustable overload settings:0.8 1 × in, adjustable shortcircuit settings: 6 10 × in 03 ( lt panel 4 & 5 & 2 3 nos )(f) mcb spn 32 amps 10 ka 01 nos(g) indicating lamps ( led type) ( r y b) 01 (set of three) (h) voltmeter digital type 0 500 voltswith inbuilt selector switch 01 no(i) ammeter digital type 0 400 amps with in built selector switch and 01 no(j) 3 line multifunctional meter 01 (nos) 67 all as per item no 61 here in before but lt panel consisting of following items ( lt panel 1 ) 68 (a) copperbus bar,100 amps , 4 ploe (b) mccb 4 pole thermal magnetic release 415 volts 63 a 16 ka,ics=100%icu ,adjustable overload settings:0.8 1×in, adjustable shortcircuit settings: 6 10×in 01(incoming)(c) mccb 4 pole thermal magnetic release 415 volts 40 a, 16 ka, ics=100%icu ,adjustable overload settings:0.8 1×in, adjustable shortcircuit settings: 6 10×in 01 ( off adm accn 01 )(d) mcb spn 16 amps 10 ka 05 nos ( office parking, single living accn, garrage for office, sentry box, street lights 05 nos )(h) indicating lamps ( led type) ( r y b) 01 (set of three)(j) voltmeter digital type 0 500 volst with inbuilt selector switch 01 no(k) ammeter digital type 0 400 amps with in built selector switch and cts 01 no(j) 3 line multifunctional meter 01(nos) 69 all as per item no 61here in before but lt panel consisting of following items ( lt panel 2 ) 70 (a) copperbus bar, 100 amps (b) mccb 4 pole thermal magnetic release 415 volts 40 a 16 ka, ics=100%icu , adjustable overload settings:0.8 1×in, adjustable shortcircuit settings: 6 10 × in 01 no (incoming), (c) mcb spn 16 amps 10 ka 15 nos(h) indicating lamps ( led type) ( r y b) (set of three) (j) voltmeter digital type 0 500 volts with inbuilt selector switch 01 no(k) ammeter digital type 0 400 amps with in built selector switch and cts 01 no 71 all as per item no 61 here in before but lt panel consisting of following items ( lt panel 3 ) 72 (a) copper bus bar, 200 amps , 4 pole(b) mccb 4 pole thermal magnetic release 415 volts 125 a 16 ka, ics=100%icu ,adjustable overload settings:0.8 1×in, adjustable shortcircuit settings: 6 10 × in 01 no (incoming), (c) mcb spn 16 amps 10 ka 05 nos(d) mcb tpn 32 amps 10 ka 03 nos(e) mccb 4 pole thermal magnetic release 63 a, 25 ka 01 no(f) indicating lamps ( led type) ( r y b) 01 (set of three) (g) voltmeter digital type 0 500 v with inbuilt selector switch 01 no(h) ammeter digital type 0 400 amps with in built selector switch and cts 01 no(l) 3 line multifunctional meter 01 (nos) 73 all as per item no 61 here in before but lt panel consisting of following items ( lt panel 4 ) 74 (a) copper bus bar, 60 amps (b) mccb 4 pole thermal magnetic release 415 volts 40 a 16 ka ics=100%icu ,adjustable overload settings:0.8 1 × in, adjustable shortcircuit settings: 6 10 × in 01 no (incoming)(c) mcb spn 16 amps 10 ka 05 nos(d) mcb tpn 16 amps 10 ka 02 nos(e) indicating lamps ( led type) ( r y b) 01 (set of three) (f) voltmeter digital type 0 500 v with inbuilt selector switch 01 no(g) ammeter digital type 0 400 a with in built selector switch and cts 01 no(h) 3 line multifunctional meter 01(no) 75 supply and installation of galvanized steel high mast lighting system of 12.5 metre in two section, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm, with 2/3 wire rope system, suitable motor for up/downand its accessories system is suitable for loading 04 nos 50 to 100 w led lights complete all as specified and directed 76 s&f pvc pipe 15 mm light grade with all fitting to cable junction box to street light fitting for cable protection with suitable size clamp, nut bolt and washerscomplete all as specified and directed 77 s&f anti climbing device,spike type fabricated out of ms bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed 78 supply and fixing mounting bracket made out of medium grade gi tubing 32mm bore 1.5 m long & bend to shape including 02 nos ms clamps, nut bolts, washers etc complete all as specified and directed 79 m&l for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than1.5 m below ground level connected to and including gi earth lead wire 4 mm dia by meansof nuts, bolts, check nuts and washer etc, made of gi and connected to test point and earth dolly all as shown in electrical plate no. 3 ssr part i 2009 and specified or indicated including excavation and earthwork in any type of soil pcc (1:3:6) type c1 in chamber, precast rcc 50 mm thick in cement concrete (1:2:4) type b 1, reinforced with welded steel wire fabric or xpm (weight not less than 4.00 kg/square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade gi watering pipe, lugs, 15 mm bore medium grade giprotection pipe, test point etc. complete all as specified and directed. note: (i) rates quoted by contyractor deemed to be includes the cost of 7.5 metre gi pipe for protection of earth lead. &f 7.5 metre gi earth lead. 80 air conditoningsupplying, installing, commissioning and testing of inverter type splitair conditioning unit 1.5 tonindoor / outdoor complete with cordless remote control unit ,high ambient cooling, adjustable mode and with in built with bee 5 star rating inverter type with cfc refrigerant 1.5 tonne capacity complete and comprising of the following : (a)refrigerant copper pipe of suction and discharge line with insulation over pipe , condensing water drain pipe & protected by suitable size of flexible pvc conduit with control valves & safety accessories including complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable, (b) fixing outdoor unit at suitable unit and supply of bracket of 2 nos for holding outdooer unit and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed. 81 sewage disposalm&l for 10 users rcc septic tanks on site to carry sewage and sullage water,excavation in any type of soil,pcc 1:4:8 below foundation,vent shaft,connection etc complete all as specified and as directed. 82 m&l for 50 users rcc septick tank designed to carry sewage and sullage water,excavation in any type of soil,pcc 1:4:8 below foundation, rcc m 30 design mix in walls,base slab, baffle walls and roof slab including beams etc with vent shafts,manholes openings with cover connection etc...complete with effective depth of 1.5 metre and overall depth of 3 metre for 50 users complete all as specified and as directed. 83 m&l for 150 users rcc septick tank designed to carry sewage and sullage water,excavation in any type of soil,pcc 1:4:8 below foundation,rcc m 30 design mix in walls,base slab,baffle walls and roof slab including beams etc with vent shafts,manholes openings with cover connection etc...complete with effective depth of 1.5 metre and overall depth of 3 metre for 50 users complete all as specified and as directed. 84 m&l for soakage wells 3.00 mtr dia x 4.50 mtr effective depth, excavation,in any type of soil,foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m 25 concrete including intercepting chamber and screen chamber made of brick masonry in cm, rcc cover slab in m 25 / sfrc, interconnecting pipes of rcc / dwc complete filled with bricks bats of size complete all as specified and as directed. (150 user rcc st) 85 m&l for soakage wells 2.40 mtr dia x 3.00 mtr effective depth, excavation,in any type of soil,foundation in pcc 1:3:6,walls of honey combed masonry with top ring of m 25 concrete including intercepting chamber and screen chamber made of brick masonry in cm, r cc cover slab in m 25 / sfrc, interconnecting pipes of rcc / dwc complete filled with bricks bats of size complete all as specified and as directed. (50 user rcc st) 86 m&l for soakage wells 1.80 mtr dia x 3.0 mtr effective depth, excavation,in any type of soil,foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m 25 concrete including intercepting chamber and screen chamber made of brick masonry in cm, rcc cover slab in m 25 / sfrc, interconnecting pipes of rcc / dwc complete filled with bricks bats of size complete all as specified and as directed. (10 user st) 87 water coolersupply, installation, commissioning of water cooler fully stainless steel, non corrosive electric driven (single phase) having approx storage capacity 80 litres self contained drinking water cooler with (non cfc refrigerent) energy efficient compressor and nominal cooling capacity of 40/80liters/hours including connecting of incoming and outgoing gi pipe medium grade and gate valve of suitable size with necessary pvc nylone braided pipe, pcc platform including drinking water provisions etc complete all as specified & directed. 88 supply and fix desert cooler plastic body , electric driven (single phase), having nominal air flow capacity of 4000 cfm , honeycomb cooling padsdesign, ice chamber, water level indicator, four way air deflection, easy mobility complete all as specified and directed 89 supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 v with accuracy of +/ 2.5 % and of capacity 4.0 kva complete all as specified and directed 90 supply, installation and commissiong of double door refrigerator , electric driven single phase, frost free , auto defrost to stop ice build up , twin cooling plus technology , led light display and control (fridge and freezer), smart connect inverter, energy efficient, less noise of cap 460 ltr complete with all fixing acessories. 91 supply, installation and commissiong of double door refrigerator , electric driven single phase , frost free , auto defrost to stop ice build up , twin cooling plus technology , led light display and control (fridge and freezer), smart connect inverter, energy efficient, less noise of cap310 ltr complete with all fixing acessories. 92 supply, installation, commissioning of metal top deep freezer having double door electric driven single phase 240 volt, 50 hz of capacity 320 liters of bee 5 star rated complete all as specified & directed. 93 lighting protection supply and fix rcc type pre cast earth pit of insidesize 300x300x300 mm size of thickness 50mm including pcc top cover complete all as specified and directed. 94 m&l for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than1.5 mtr below ground level connected to and including gi earth lead strip 32 x 6 mm by meansof nuts, bolts, check nuts and washer etc, made of gi and connected to test point and earth dolly all as shown in electrical plate no. 3 ssr part i 2009 and specified or indicated including excavation and earthwork in any type of soil pcc (1:3:6) type c1 in chamber, precast rcc 50 mm thick in cement concrete (1:2:4) type b1, reinforced with welded steel wire fabric or xpm (weight not less than 4.00 kg/square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade gi watering pipe, lugs, 40 mm bore medium grade giprotection pipe, test point etc. complete all as specified and directed. note: (i) rates quoted by contyractor deemed to be includes the cost of 7.5 metre gi pipe for protection of earth lead. &f 7.5 metre gi earth lead. 95 rain water harvestingm&l for construction of rain water harvesting pit complete all as specified and shown on drawing as per td drawing ce (fy) hyderabad td no td/str/14. 96 arboriculturesurface excavation in any type of soil not exceeding 30cm deep and averaging upto 15cm and removing up to a distance n exc 50 metre filling back / spreading with red earth of 15 cm thick mixed with farm yard treating the soil with pesticides (i.e bavitin and neam cake bhc 10% linsondustthimment and phorate, super and vermi compost in ratio (1:3) incl turfing/laying of(bermuda grass (cynodon dactylon), buffalo grass (stenotaphrum secundatum) & korean lawn grass (zoysia japonica) ready made of approved quality turfs side by side without undualation/depressions and ramming the surface complete all as directed by engineer in charge. 97 digging of pit not exc 0.25 cum in any type of soil incl removal and filling back to pit with suitable growing media like red earth by treating with farm yead manure in the ratio (3:1) fertilizers and pesticides (i.e bevation and neem cake bhc 10% linson dust.thimment or phorate, manures super and vermicompost) and making up the trenh area to proper level including supply and planting tree plants of species of height not less than 3 ft such as neem (azadirachta indica), gulmohar (delonix regia), peepal tree (ficus religiosa), banyan (ficus benghalensis), pink cassia (cassia javanica) as approved by ge etc as directed by engr in charge. 98 all as per item no 88 above but decorative plants such as christmas tree (araucaria heterophylla), golden cane palm (dypsis lutescens), royal palm (roystonea regia), foxtail palm (wodyetia bifurcata) & false ashoka (monoon longifolium) as directed by engr in charge. 99 pronv of ms tree guard 450 mm dia, 1.50 mtr high with ms wiremesh of size 78mm x 37mm and 2mm dia of wire and ms angle iron 20 x 20 x 3mm verticals (3 nos) 1.95 m long, 30 cm burried in ground & ms flats 14 x 3 mm around the tree guard (3 nos @ top, middle and bottom) equally spaced and embedded vertical angles in pcc 1:3:6 type c 1 including excavation in post holes and removal of excavated soil to a n. exc. 50 mtr and applying two coat of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed. 100 maintenance of planted trees and lawn area for two year after certified date of completion issued by ge (srl item no 87 to 90above)by employing one experienced mali per day. the maintenance shall includes the following.(a) periodical de weeding of unwanted vegetation growth around the plants/lawn area(b) watering all the trees/plants/grass and soil with required for proper growth.(c) periodical prunning the shrubs.(d) periodical lawn mowing(e) treating the trees/plants grass and soil with required quantity of approved manure,pesticides and fertilizer including necessary toping of red earth(f)replacement of dried/dead plants/grass/trees.(g) hose pipe to be arranged by the contractor.(h) water shall be supplied by deptt only for watering to plants. ...
Due Date : October 19, 2024
Tender Value : ₹ 19 Crore