Arcelor Mittal Nippon Steel India Limited - Gujarat

40157251 tender for supply of sys, ot, replacement of discontinue dhardwar,. system,one time details:replacement of discontinued hardware and control system of ims profile gauge of hsm details 1:23 ca001 102 details 2:supply and retrofitting of xrg 225 / 1000 x ray generator and hv cable r24si with software 2 sets details 3:supply and retrofitting of drive system with oscillation unit and crankshaft with required software 1 set details 4:hmi and controlling software amns ref. no(wbs):c 23 ca001 102 , make name:ims...

Western Railway - Gujarat

24192999 supply of , mobile x ray unit (x ray generator with mobile stand) (specification attached) warrenty:2 year brand: medion healthcare, movx mi 100 or similar it should be interfaced and integrated with the existing cr system (konica minolta : computed radiography regius sigma ii) of railway hospital rajkot....

Western Railway - Gujarat

24180379 supply of , mobile x ray unit (x ray generator with mobile stand) (specification attached) warrenty:2 year brand: medion healthcare, movx mi 100 or similar it should be interfaced and integrated with the existing cr system (konica minolta : computed radiography regius sigma ii) of railway hospital rajkot....

Western Railway - Gujarat

24169663 supply of , mobile x ray unit (x ray generator with mobile stand) (specification attached) warrenty:2 year brand: medion healthcare, movx mi 100 or similar it should be interfaced and integrated with the existing cr system (konica minolta : computed radiography regius sigma ii) of railway hospital rajkot....

Surat Municipal Corporation - Gujarat

16879571 tender for supplying and installing equipments / instruments for the department of surgery of smimer item no.1 : 9 inch high frequency microprocessor based c arm machine to be used for ercp procedures 1. high frequency x ray generator: 2. x ray tube: 3. image intensifier: 4. tv camera system: 5. tv monitor 6. c arm movements and safety item no.2 : burr hole set with electric craniotome item no.3 : basic instrument in laparoscopy set ( per set ) item no.4 : uroflometry item no.5 : assorted surgical instrument for minor operation sets item no.6 : general sets including open urological surgery set etc....

Western Railway - Gujarat

13025741 supply of high frequency mobil xray machines 150/ma,110kv high frequency xray machine[40khz] withspring balanced mobils stand] special features 40khz less skin dose 6.kw. maximum ma 150ma mas range 1 200mas. self diagnostic program with indicators for earth fault error . kv error filament error special features 40khz less skin dose x ray generator type high frequency microprocessor controlled power output 6k.w kv range 40to 110kvp in kv/step maximum ma 150ma. mas range1 200mas control attractive and ergonomically designed control pannel with total soft fether touch switcches for various operations having following functions and indications [1] machine on/off switch [2]digital display of kv and mas. [3] kv and mas increase and decrease switches. [4] ready and x ray on switch with indicators. [5] bucky selection switch. [6] collimator lamp on switch. [7]stand by and exposure release switch. [8] self diagnostic progra,m with indicatros for earth fault error , kv error, filament error. ,filament error tube head thermal overload. xray on indicator incoming voltage indicator. anatomical programining up to 216 pre programmed functions in which automatic selection of factrs is done accordingly to the body part selection. a two step hand switch with dual action for exposure release with retractalle cord is provided for taking image from a safer distance. xray tube head monoblock version x ray tube head is provided. the monoblock consists of x ray tube, h.v. transformet,filament transformer. h.v. rectifires and capacitors, all immersed in high grade oil with dielectric strength. monoblock tube head is protected for thermal overload. tube anode type stationary anode nominal focal spot 2.6mm anode heat storage capacity 35kj collmator a geared light beam diaphragm with white power led [for higher luminosity and lower electrical consumption ] for adjustment of exposure area is provided and there is a provision of auto shut off af...

Western Railway - Gujarat

12918457 supply of high frequency mobil xray machines 150/ma,110kv high frequency xray machine[40khz] withspring balanced mobils stand] special features 40khz less skin dose 6.kw. maximum ma 150ma mas range 1 200mas. self diagnostic program with indicators for earth fault error . kv error filament error special features 40khz less skin dose x ray generator type high frequency microprocessor controlled power output 6k.w kv range 40to 110kvp in kv/step maximum ma 150ma. mas range1 200mas control attractive and ergonomically designed control pannel with total soft fether touch switcches for various operations having following functions and indications [1] machine on/off switch [2]digital display of kv and mas. [3] kv and mas increase and decrease switches. [4] ready and x ray on switch with indicators. [5] bucky selection switch. [6] collimator lamp on switch. [7]stand by and exposure release switch. [8] self diagnostic progra,m with indicatros for earth fault error , kv error, filament error. ,filament error tube head thermal overload. xray on indicator incoming voltage indicator. anatomical programining up to 216 pre programmed functions in which automatic selection of factrs is done accordingly to the body part selection. a two step hand switch with dual action for exposure release with retractalle cord is provided for taking image from a safer distance. xray tube head monoblock version x ray tube head is provided. the monoblock consists of x ray tube, h.v. transformet,filament transformer. h.v. rectifires and capacitors, all immersed in high grade oil with dielectric strength. monoblock tube head is protected for thermal overload. tube anode type stationary anode nominal focal spot 2.6mm anode heat storage capacity 35kj collmator a geared light beam diaphragm with white power led [for higher luminosity and lower electrical consumption ] for adjustment of exposure area is provided and there is a provision of auto shut off af...