Bids Are Invited For S. I. -E-S, L-F ( Q3 ) Ese Air Terminal: Supply Of Ese Lightning Arrester Prevectron 3. Controlled Early Streamer Emission Air Terminal ( Ceseat ) , The Ceseat Shall Be Tested And Certified In A High Voltage Laboratory To Withstand More Than 200Ka, Complaint With Nfc 17102:2011, Une 21186:2011 & Np 4426:2013, Optimum Lightning Protection Performance Achieved By Adopting The Psatented Optimax* Technology In Designing The Ceseat, The Ceseat Should Be Certified To Withstand Real-Time Lightning Tests, Following Tests To Be Performed In Compliance With The New Test Guidelines In Annex C Of The Revised Nfc 17 102 Version 2011 For Ese Lightning Protection System And Due Certification Required From The Ese-Manufacturer For: A. Marking Tests B. Mechanical Tests C. Environmental Tests D. Electrical Tests E. At Tests F. Emc Tests, Ceseat Must Be Ce-Marked For Compliance To Nf En 611000-6-2 / Nf En 611000-6-3., The Ceseat Shall Be Made Of Stainless Steel 316 Grade Non-Corrosive Metallic Components., The Device To Be A Fully Autonomous System Requiring No External Power Supply. Testing Feature And Modular Design Enabling To Repair / Replace Defective Components. The Ceseat Should Be Sustainably Designed To Mitigate Its Environmental Impact. Warranty: 5 Years ( 60 Months ) . 15 Nos. Elevated Mast / Mounting Structure: Elevation Pole Made Of Class B Gi- Material Having Isi-Marking. Consists Of The Following ( For A Typical Sm Mast ) : A. 3Mtrx 60Mm Dia Gl Pipe B. 2.5Mtr X 50Mm Dia Gl Pipe C. Reducer, M20 Thread D. Base Plate ( 200X200x10mm ) , Mounting Bracket, Clamps And All Required Fixing Accessories Supplied In Compliance With Iec 62561-1-15 Nos. Performance Recording Equipment: Supply Of Indelec Lightning Flash Counter. Electronically Controlled. A. Strike Detection Range: 1 Ka To 100 Ka. B. Minimum Current Sensitivity ( Id / 3 ) : 333 A C. Protection Class: Ip54 D. Standards Applicable: Ute C 17-106: Tested In High Voltage Laboratory ( Cpr ) For 8 / 20Us 40Ka Current Impulse. Compliant To Iec 62 561-6-15 Nos. Down Conductor: Supply Of Down Conductor Made Of Copper Cable. It Should Have A Minimum Cross Sectional Area Of 50Mm To Withstand 250Ka Lightning Current And Comply With Nfc / Iec 62305 Standard. Cable Shall Necessarily Have 19-Strands Across The 50Sqmm Cross-Section, With Each Strand Dia Of Min 1.8Mm. 750 Mtr. Test Link: Test Link Allowing Down Conductor To Be Disconnected From The Earthing Point So That The Earth Resistance May Be Measured. Compliant With Iec 62561-1-30 Nos. Maintenance Free Earthing Electrode: Maintenance Free Single Rod, Copper Bonded Earthing System - Dia 17.2Mm; 3Meters Supply Of Copper-Bonded Earthing Electrode Of 3Mts Length And 17.2Mm Dia With Minimum Copper Bonding Of 250Micron. The Electrode Shall Be Duly Tested And Certified By Cpri ( Central Power Research Institute ) , Govt Of India. Brass Rod-To-Conductor Connectors Should Also Be Supplied For Earth Strip Connection. To Ensure The Moisture Content And Electrical Conductivity, Z-Earth, Carbon Based Carbofill Compound Shall Be Used As A Backfill Compound. Minimum 40 Kgs Of Carbon Backfill Compound Shall Be Used Along With Each Earthing Electrode. The Chemical Backfill Compound Shall Be Tested & Certifed By Any Approved & Accredited Laboratory In India. System Shall Be In Full Compliance With Is:3043 Earthing Standards A. Copper Bonded Steel Earth Rod-Dia. 17.2 Mm-Length 3 Mts, 1No / 5Kgs B. Rod-To-Conductor Connector-For 17.2Mm Dia Rods Ino / 0.12Kgs C.Z-Earth-Ground Enhancing Compound-20 Kgs Each, 2Bags / 40Kgs With Earth Pit Chamber - 30 Nos. Installation Bill Of Quantities: A. Ese Lightning Arrestor Mounting As Per Lightning Protection Design B. Anchoring Of The Mounting Mast On Which The Ese Air Terminal Is To Be Mounted C. Routing & Down Conductor Laying As Per Lightning Protection Standards D. Installation Of Link Box F. Chemical Maintenance-Free Earthing System Installation: Boring / Auguring / Backfill Compound Preparation & Fill-Up / Curing & Compaction Of Backfill / Measurement Of Earth Pit Resistance In Compliance With 153043 Earthing Standards G.Concrete Structure. -15 Nos. Total Quantity : 1

Tender Notice

39203457

Indian


Gujarat

September 01, 2023

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Bids Are Invited For S. I. -E-S, L-F ( Q3 ) Ese Air Terminal: Supply Of Ese Lightning Arrester Prevectron 3. Controlled Early Streamer Emission Air Terminal ( Ceseat ) , The Ceseat Shall Be Tested And Certified In A High Voltage Laboratory To Withstand More Than 200Ka, Complaint With Nfc 17102:2011, Une 21186:2011 & Np 4426:2013, Optimum Lightning Protection Performance Achieved By Adopting The Psatented Optimax* Technology In Designing The Ceseat, The Ceseat Should Be Certified To Withstand Real-Time Lightning Tests, Following Tests To Be Performed In Compliance With The New Test Guidelines In Annex C Of The Revised Nfc 17 102 Version 2011 For Ese Lightning Protection System And Due Certification Required From The Ese-Manufacturer For: A. Marking Tests B. Mechanical Tests C. Environmental Tests D. Electrical Tests E. At Tests F. Emc Tests, Ceseat Must Be Ce-Marked For Compliance To Nf En 611000-6-2 / Nf En 611000-6-3., The Ceseat Shall Be Made Of Stainless Steel 316 Grade Non-Corrosive Metallic Components., The Device To Be A Fully Autonomous System Requiring No External Power Supply. Testing Feature And Modular Design Enabling To Repair / Replace Defective Components. The Ceseat Should Be Sustainably Designed To Mitigate Its Environmental Impact. Warranty: 5 Years ( 60 Months ) . 15 Nos. Elevated Mast / Mounting Structure: Elevation Pole Made Of Class B Gi- Material Having Isi-Marking. Consists Of The Following ( For A Typical Sm Mast ) : A. 3Mtrx 60Mm Dia Gl Pipe B. 2.5Mtr X 50Mm Dia Gl Pipe C. Reducer, M20 Thread D. Base Plate ( 200X200x10mm ) , Mounting Bracket, Clamps And All Required Fixing Accessories Supplied In Compliance With Iec 62561-1-15 Nos. Performance Recording Equipment: Supply Of Indelec Lightning Flash Counter. Electronically Controlled. A. Strike Detection Range: 1 Ka To 100 Ka. B. Minimum Current Sensitivity ( Id / 3 ) : 333 A C. Protection Class: Ip54 D. Standards Applicable: Ute C 17-106: Tested In High Voltage Laboratory ( Cpr ) For 8 / 20Us 40Ka Current Impulse. Compliant To Iec 62 561-6-15 Nos. Down Conductor: Supply Of Down Conductor Made Of Copper Cable. It Should Have A Minimum Cross Sectional Area Of 50Mm To Withstand 250Ka Lightning Current And Comply With Nfc / Iec 62305 Standard. Cable Shall Necessarily Have 19-Strands Across The 50Sqmm Cross-Section, With Each Strand Dia Of Min 1.8Mm. 750 Mtr. Test Link: Test Link Allowing Down Conductor To Be Disconnected From The Earthing Point So That The Earth Resistance May Be Measured. Compliant With Iec 62561-1-30 Nos. Maintenance Free Earthing Electrode: Maintenance Free Single Rod, Copper Bonded Earthing System - Dia 17.2Mm; 3Meters Supply Of Copper-Bonded Earthing Electrode Of 3Mts Length And 17.2Mm Dia With Minimum Copper Bonding Of 250Micron. The Electrode Shall Be Duly Tested And Certified By Cpri ( Central Power Research Institute ) , Govt Of India. Brass Rod-To-Conductor Connectors Should Also Be Supplied For Earth Strip Connection. To Ensure The Moisture Content And Electrical Conductivity, Z-Earth, Carbon Based Carbofill Compound Shall Be Used As A Backfill Compound. Minimum 40 Kgs Of Carbon Backfill Compound Shall Be Used Along With Each Earthing Electrode. The Chemical Backfill Compound Shall Be Tested & Certifed By Any Approved & Accredited Laboratory In India. System Shall Be In Full Compliance With Is:3043 Earthing Standards A. Copper Bonded Steel Earth Rod-Dia. 17.2 Mm-Length 3 Mts, 1No / 5Kgs B. Rod-To-Conductor Connector-For 17.2Mm Dia Rods Ino / 0.12Kgs C.Z-Earth-Ground Enhancing Compound-20 Kgs Each, 2Bags / 40Kgs With Earth Pit Chamber - 30 Nos. Installation Bill Of Quantities: A. Ese Lightning Arrestor Mounting As Per Lightning Protection Design B. Anchoring Of The Mounting Mast On Which The Ese Air Terminal Is To Be Mounted C. Routing & Down Conductor Laying As Per Lightning Protection Standards D. Installation Of Link Box F. Chemical Maintenance-Free Earthing System Installation: Boring / Auguring / Backfill Compound Preparation & Fill-Up / Curing & Compaction Of Backfill / Measurement Of Earth Pit Resistance In Compliance With 153043 Earthing Standards G.Concrete Structure. -15 Nos. Total Quantity : 1