Tender For Supply Of Powergrid Ss51t-765Kv Gis ( Jamnagar ) --1 Gis Bay: 765Kv, 3150 A, 50 Ka, Sf6 Gis Ict Feeder Baymodule As Per Section-Project, Technical Specification 2 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Bus Reactor Feeder Baymodule As Per Section-Project, Technical Specification 3 Gis Bay: 765Kv, 3150A , 50Ka, Gis Line Feeder Baymodule ( With Pir ) As Per Section-Project, Technical Specification 4 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( With Pir ) As Per Section-Project, Technical Specification 5 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Switchable Line Reactor Feeder Baymodule As Per Section-Project, Technical Specification 6 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( Without Pir ) As Per Section-Project, Technical Specification 7 Gis: 765Kv, 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Transformer As Per Section-Project, Technical Specification 8 Gis: 765Kv, , 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Reactor As Per Section-Project, Technical Specification 9 Gis: 765Kv, 4000A, 50Ka, Sf6 Gis Bus Bar Module As Per Section-Project, Technical Specification 10 Gis: 765Kv, 3150A, 50Ka, Single Phase Sf6 To Air Bushing 11 Gis: 765Kv, , 3000 / 3150 A, 50Ka, 1 Phase, Sf6 Gas Insulated Bus Duct ( Gib ) Outside Gis Hall 12 Gis: Controlled Switching Device ( Csd ) For 765 Kv, 3 Phase Circuit Breaker 13 Gis: Local Control Cubicles ( Lcc ) 14 Gis T&M Equipment: Sf6 Gas Filling And Evacuation Plant For 765Kv Gis Station 15 Gis T&M Equipment:Portable Partial Discharge Measurement Test Kitwith All Necessary Accessories, Industrial Grade Laptop And Licensedsoftware As Per Technical Specification. 16 Gis T&M Equipment: Sf6 Gas Analyzer 17 Gis T&M Equipment: Sf6 Gas Leakage Detector 18 Gis T&M Equipment: Portable Scissor Lift 19 Spares: 765Kv Gis- Sf6 Gas Pressure Relief Device Assembly Of Each Type 20 Spares: 765Kv Gis-Sf6 Pressure Gauge Cum Switch / Density Monitors And Pressureswitch As Applicable, Of Each Type 21 Spares: 765Kv Gis- Coupling Device For Pressure Gauge Cum Switch For Connectinggas Handling Plant Of Each Type 22 Spares: 765Kv Gis- Rubber Gaskets, O Rings And Seals For Sf6 Gas For Gisenclosure Of Each Type 23 Spares: 765Kv Gis- Molecular Filter For Sf6 Gas With Filter Bags ( 5% Of Total Weight ) 24 Spares: 765Kv Gis- Control Valves For Sf6 Gas Of Each Type 25 Spares: 765Kv Gis- Sf6 Gas ( 5% Of Total Gas Quantity ) 26 Spares: 765Kv Gis- Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism 27 Spares: 765Kv Gis- Uhf Pd Sensors Of Each Type Along With Bnc Connector For 765Kv Gis 28 Spares: 765Kv Gis- Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields 29 SPARES: 765KV GIS- GAS BARRIERS OF EACH TYPE(COMPLETE WITH METAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS 30 SPARES: 765KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT 31 SPARES: 765KV GIS- LCC SPARES - AUX. RELAYS,CONTACTORS, PUSH BUTTONS,SWITCHES,LAMPS, ANNUNCIATION WINDOWS,MCB,FUSES, TIMERS,TERMINAL BLOCKS ETC. OF EACHTYPE & RATING 32 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER,MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT 33 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER, MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT 34 SPARES: 765KV GIS- Trip coil assembly with resistor for 765kV GIS Circuit Breaker(As applicable) 35 SPARES: 765KV GIS- Closing coil assembly with resistor for765 kV GIS Circuit Breaker(As applicable) 36 SPARES: 765KV GIS- RELAYS,POWER CONTACTORS,PUSH BUTTONS,TIMERS & MCBS ETC.(AS APPLICABLE)OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER 37 SPARES: 765KV GIS- Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker 38 SPARES: 765KV GIS- OPERATION COUNTER for 765kV GIS Circuit Breaker 39 SPARES: 765KV GIS- HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765kV GIS Circuit Breaker 40 SPARES: 765KV GIS- HYDRAULIC FILTER OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 41 SPARES: 765KV GIS- HOSE PIPE OF EACH TYPE(AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 42 SPARES: 765KV GIS - N2 ACCUMULATOR(FOR HYDRAULIC OPERATEDMECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 43 SPARES: 765KV GIS- VALVES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 44 SPARES: 765KV GIS- PIPE LENGTH(COPPER & STEEL)OF EACH SIZE & TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 45 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 46 SPARES: 765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 47 SPARES: 765KV GIS- HYDRAULIC OIL(5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 48 SPARES:765KV GIS- PRESSURE RELIEF DEVICE OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 49 SPARES: 765KV GIS- COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC.(FOR SPRING OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 50 SPARES: 765KV GIS- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC.(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 51 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER(For Hydraulic-Spring Operated Mechanism,if applicable) for 765KV GIS CIRCUIT BREAKER 52 SPARES:765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 53 SPARES: 765kV GIS- Single phase of 3150Adisconnector switch including maincircuit,enclosure,driving mechanismand support insulator etc.,complete in all respect 54 SPARES: 765KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT,ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT 55 SPARES: 765KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE INALL RESPECT 56 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS DISCONNECTORSWITCH 57 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS MAINTENANCE EARTH SWITCH 58 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS FAST EARTHING SWITCH 59 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR DISCONNECTOR 60 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH 61 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH(IF APPLICABLE) 62 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 63 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS MAINTENANCE EARTH SWITCH 64 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 65 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 66 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KVGIS MAINTENANCE EARTH SWITCH 67 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 68 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(3 CORES,TYPE-CTA) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 69 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(2 CORES,TYPE-CTB) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 70 SPARES: 765KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT 71 SPARES: 765KV GIS- TRANSDUCER FOR CB & CSD 72 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- GIS METALLIC ENCLOSURE 73 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- EXPANSION BELLOWS/ JOINTS 74 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- TEE BEND 75 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- L BEND 76 SERVICES- 765kV GIS: SUPERVISION OF ERECTION OF GIS 77 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT 78 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING 79 SERVICES- 765kV GIS:TESTING & COMMISSIONING OF GIS 80 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT 81 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF SF6 TO AIR BUSHING 82 SERVICES- 765kV GIS : FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR 83 SERVICES- 765kV GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM 84 SERVICES- 765kV GIS : TRAINING FOR GIS AT SITE 85 SERVICES- 765kV GIS : TRAINING FOR GIS AT MANUFACTURER WORKS 86 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS 87 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS 88 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM 89 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GISTESTING & COMMISSIONING TEAM 90 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION & REMOBILIZATION CHARGES OFHV TEST KIT ALONG WITH OPERATOR

Tender Notice

43178564

Indian


Gujarat

May 03, 2024

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Supply Of Powergrid Ss51t-765Kv Gis ( Jamnagar ) --1 Gis Bay: 765Kv, 3150 A, 50 Ka, Sf6 Gis Ict Feeder Baymodule As Per Section-Project, Technical Specification 2 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Bus Reactor Feeder Baymodule As Per Section-Project, Technical Specification 3 Gis Bay: 765Kv, 3150A , 50Ka, Gis Line Feeder Baymodule ( With Pir ) As Per Section-Project, Technical Specification 4 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( With Pir ) As Per Section-Project, Technical Specification 5 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Switchable Line Reactor Feeder Baymodule As Per Section-Project, Technical Specification 6 Gis Bay: 765Kv, 3150A, 50Ka, Sf6 Gis Tie Baymodule ( Without Pir ) As Per Section-Project, Technical Specification 7 Gis: 765Kv, 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Transformer As Per Section-Project, Technical Specification 8 Gis: 765Kv, , 3150A, 50Ka, Sf6 Gis Auxiliary Busmodule For Spare Reactor As Per Section-Project, Technical Specification 9 Gis: 765Kv, 4000A, 50Ka, Sf6 Gis Bus Bar Module As Per Section-Project, Technical Specification 10 Gis: 765Kv, 3150A, 50Ka, Single Phase Sf6 To Air Bushing 11 Gis: 765Kv, , 3000 / 3150 A, 50Ka, 1 Phase, Sf6 Gas Insulated Bus Duct ( Gib ) Outside Gis Hall 12 Gis: Controlled Switching Device ( Csd ) For 765 Kv, 3 Phase Circuit Breaker 13 Gis: Local Control Cubicles ( Lcc ) 14 Gis T&M Equipment: Sf6 Gas Filling And Evacuation Plant For 765Kv Gis Station 15 Gis T&M Equipment:Portable Partial Discharge Measurement Test Kitwith All Necessary Accessories, Industrial Grade Laptop And Licensedsoftware As Per Technical Specification. 16 Gis T&M Equipment: Sf6 Gas Analyzer 17 Gis T&M Equipment: Sf6 Gas Leakage Detector 18 Gis T&M Equipment: Portable Scissor Lift 19 Spares: 765Kv Gis- Sf6 Gas Pressure Relief Device Assembly Of Each Type 20 Spares: 765Kv Gis-Sf6 Pressure Gauge Cum Switch / Density Monitors And Pressureswitch As Applicable, Of Each Type 21 Spares: 765Kv Gis- Coupling Device For Pressure Gauge Cum Switch For Connectinggas Handling Plant Of Each Type 22 Spares: 765Kv Gis- Rubber Gaskets, O Rings And Seals For Sf6 Gas For Gisenclosure Of Each Type 23 Spares: 765Kv Gis- Molecular Filter For Sf6 Gas With Filter Bags ( 5% Of Total Weight ) 24 Spares: 765Kv Gis- Control Valves For Sf6 Gas Of Each Type 25 Spares: 765Kv Gis- Sf6 Gas ( 5% Of Total Gas Quantity ) 26 Spares: 765Kv Gis- Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism 27 Spares: 765Kv Gis- Uhf Pd Sensors Of Each Type Along With Bnc Connector For 765Kv Gis 28 Spares: 765Kv Gis- Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields 29 SPARES: 765KV GIS- GAS BARRIERS OF EACH TYPE(COMPLETE WITH METAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS 30 SPARES: 765KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT 31 SPARES: 765KV GIS- LCC SPARES - AUX. RELAYS,CONTACTORS, PUSH BUTTONS,SWITCHES,LAMPS, ANNUNCIATION WINDOWS,MCB,FUSES, TIMERS,TERMINAL BLOCKS ETC. OF EACHTYPE & RATING 32 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER,MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT 33 SPARES: 765KV GIS- ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER, MAIN CIRCUIT,ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT 34 SPARES: 765KV GIS- Trip coil assembly with resistor for 765kV GIS Circuit Breaker(As applicable) 35 SPARES: 765KV GIS- Closing coil assembly with resistor for765 kV GIS Circuit Breaker(As applicable) 36 SPARES: 765KV GIS- RELAYS,POWER CONTACTORS,PUSH BUTTONS,TIMERS & MCBS ETC.(AS APPLICABLE)OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER 37 SPARES: 765KV GIS- Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker 38 SPARES: 765KV GIS- OPERATION COUNTER for 765kV GIS Circuit Breaker 39 SPARES: 765KV GIS- HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765kV GIS Circuit Breaker 40 SPARES: 765KV GIS- HYDRAULIC FILTER OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 41 SPARES: 765KV GIS- HOSE PIPE OF EACH TYPE(AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 42 SPARES: 765KV GIS - N2 ACCUMULATOR(FOR HYDRAULIC OPERATEDMECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 43 SPARES: 765KV GIS- VALVES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 44 SPARES: 765KV GIS- PIPE LENGTH(COPPER & STEEL)OF EACH SIZE & TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 45 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM,IFAPPLICABLE) for 765KV GIS CIRCUIT BREKAER 46 SPARES: 765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULICOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 47 SPARES: 765KV GIS- HYDRAULIC OIL(5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 48 SPARES:765KV GIS- PRESSURE RELIEF DEVICE OF EACH TYPE(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 49 SPARES: 765KV GIS- COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC.(FOR SPRING OPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 50 SPARES: 765KV GIS- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC.(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREAKER 51 SPARES: 765KV GIS- PRESSURE SWITCHES OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER(For Hydraulic-Spring Operated Mechanism,if applicable) for 765KV GIS CIRCUIT BREAKER 52 SPARES:765KV GIS- PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE(FOR HYDRAULIC-SPRINGOPERATED MECHANISM,IF APPLICABLE) for 765KV GIS CIRCUIT BREKAER 53 SPARES: 765kV GIS- Single phase of 3150Adisconnector switch including maincircuit,enclosure,driving mechanismand support insulator etc.,complete in all respect 54 SPARES: 765KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT,ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT 55 SPARES: 765KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE,DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE INALL RESPECT 56 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS DISCONNECTORSWITCH 57 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS MAINTENANCE EARTH SWITCH 58 SPARES: 765KV GIS- OPEN/ CLOSE CONTACTOR ASSEMBLY,TIMERS,KEY INTERLOCK,INTERLOCKINGCOILS,RELAYS,PUSH BUTTONS,INDICATING LAMPS,POWER CONTACTORS, RESISTORS,FUSES,MCBS & DRIVE CONTROL CARDS ETC.(AS APPLICABLE)ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS FAST EARTHING SWITCH 59 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR DISCONNECTOR 60 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH 61 SPARES: 765KV GIS- LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH(IF APPLICABLE) 62 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 63 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS MAINTENANCE EARTH SWITCH 64 SPARES: 765KV GIS- DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 65 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH 66 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KVGIS MAINTENANCE EARTH SWITCH 67 SPARES: 765KV GIS- MOTOR FOR DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH 68 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(3 CORES,TYPE-CTA) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 69 SPARES: 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER(2 CORES,TYPE-CTB) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT 70 SPARES: 765KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT 71 SPARES: 765KV GIS- TRANSDUCER FOR CB & CSD 72 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- GIS METALLIC ENCLOSURE 73 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- EXPANSION BELLOWS/ JOINTS 74 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- TEE BEND 75 SPARES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS-SPARES: 765KV GIS- L BEND 76 SERVICES- 765kV GIS: SUPERVISION OF ERECTION OF GIS 77 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT 78 SERVICES- 765kV GIS:SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING 79 SERVICES- 765kV GIS:TESTING & COMMISSIONING OF GIS 80 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT 81 SERVICES- 765kV GIS : TESTING & COMMISSIONING OF SF6 TO AIR BUSHING 82 SERVICES- 765kV GIS : FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR 83 SERVICES- 765kV GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM 84 SERVICES- 765kV GIS : TRAINING FOR GIS AT SITE 85 SERVICES- 765kV GIS : TRAINING FOR GIS AT MANUFACTURER WORKS 86 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS 87 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS 88 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM 89 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GISTESTING & COMMISSIONING TEAM 90 SERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES: SERVICES- 765kV GIS: DEMOBILIZATION & REMOBILIZATION CHARGES OFHV TEST KIT ALONG WITH OPERATOR