Tender For Pr-28035998-Relay_Corex 28035998 0001 0001 300900891 RELAY,PROTCTN,PN:7SR5110-2AA11-0AA0/BB Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 24 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR5110-2AA11-0AA0/BB Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 3 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 2 28035998 0002 0002 300900870 RELAY,PROTCTN,PN:7SR1004-3KB20-2CA0/EE Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 6 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR1004-3KB20-2CA0/EE Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay. Also vendor must provide Relay to PC communication cable with each relay. 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 4 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 3 28035998 0003 0003 300892229 RELAY,PROTCTN,PN:7SR1726-4NA12-2CA0,MUL Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 9 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR1726-4NA12-2CA0 Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 5 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 4 28035998 0004 0004 300386715 RELAY,P/N:SR71,F/A.C CIRCUIT BRAKER Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 5 NO RELAY PART NO : SR71 , MAJOR EQUIPMENT : A.C CIRCUIT BRAKER MAJOR EQUIPMENT MODEL : CN-CS , MAJOR EQUIPMENT MAKE : L AND T ADDITIONAL INFORMATION : MICROPROCESSOR BASED RELAY FOR 800/1250/1600 AMP ACB Item Details : Item Note : 5 28035998 0005 0005 300442098 METER,P/N:EM6436,F/VFD&LT PANEL Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 20 NO ASSY/PARTS ITEM NAME : METER , PART NO : EM6436 MAJOR EQUIPMENT : ABB VFD AND LT PANEL MAJOR EQUIPMENT MODEL : YN3A210354 , MAJOR EQUIPMENT MAKE : ABB Item Details : WITH RS485 Item Note :

Tender Notice

43579471

Indian


Gujarat

June 15, 2024

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Pr-28035998-Relay_Corex 28035998 0001 0001 300900891 RELAY,PROTCTN,PN:7SR5110-2AA11-0AA0/BB Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 24 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR5110-2AA11-0AA0/BB Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 3 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 2 28035998 0002 0002 300900870 RELAY,PROTCTN,PN:7SR1004-3KB20-2CA0/EE Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 6 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR1004-3KB20-2CA0/EE Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay. Also vendor must provide Relay to PC communication cable with each relay. 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 4 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 3 28035998 0003 0003 300892229 RELAY,PROTCTN,PN:7SR1726-4NA12-2CA0,MUL Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 9 NO RELAY,PROTECTION TYPE:NUMERICAL , TRIPPING:MULTIFUNCTION , MAKE NAME:SIEMENS MAKE PART NO:7SR1726-4NA12-2CA0 Item Details : Supply, Retrofitting, Testing <(>&<)> Commissioning of Siemens Make Relay 1. Relay require with Front protective cover. 2. Vendor must provide all related hardware required for retrofitting job like, masking box, mounting accessories, wires/cables, lugs etc. 3. AMNS will provide individual feeder shutdown and remaining all activities (up to load trial with AMNS representatives) needs to be carried out by vendor. 4. Relay needs to be fixed in existing cut-out. If dimensions are not as per cut-out, then suitable arrangement to be supplied and installed by vendor. 5. Vendor must submit detailed drawings of each modification along with wiring diagram and programming for approval. 6. Vendor should provide software and communication cable for each type of relay which is going to be retrofitted. 7. One by one installation of new relay as per shutdown/clearance availability and vendor must complete entire job. 8. Relay parameterization and I/O s to be programmed by vendor as per existing one. Also, during load trial vendor must be available. 9. Relay testing to be ensured by vendor in presence of AMNS Engineer. 10. Required tools and tackles must be in vendor scope. 11. At a time only one feeder will be given for modification and remaining feeders upper / lower will be in running condition. 12. Deputed team members must have at least ITI qualification with supervisor. 13. Masking of cut outs with matching colour plate. 14. After installation, one year support to be provided by vendor like faulty component replacement, repairing/replacement of faulty component etc. Scope of Work- AMNS / INDIA: 1. Permit to work will be provided. Certification: 1. Medical fitness certificate: All the staff of the contractor must undergo medical checkup at our Care Nursing Home, AM/NS Township, Hazira before starting work at AMNS. This would be done as per AM/NS India standards and its cost shall be borne by the vendor. 2. Work at Height certificate approved by AMNS authorities is pre-required which is to be fulfilled by the contractor. 3. Gate pass for plant entry at AMNS is to be generated by the contractor for all his staff. Here, to be noted that we at AMNS are h aving our own Secures Access system called SCRUM at Hazira Site which is use for processing the Gate Pass. PPES: To be provided by contractor. 1. Safety Helmet – as recommended by AMNS Safety authority. 2. Hand Gloves - Cotton 3. Safety Goggles – as recommended by AMNS Safety authority. 4. Safety Shoes – as recommended by AMNS Safety authority. 5. Dust Mask 6. Rain gears Transportation Notes: - Movement of Manpower / Associates at AMNS Hazira Site. 1. No Pedestrian/Cycles/Two Wheelers movement is allowed inside the Plant Premises. 2. The Vendor must ensure availability of sufficient buses/vehicles to ply their associates inside AMNS facility up to plant premises. Vendors ensure safe transportation of their associates from their place of residence to respective work location in the plant and back. . Item Note : Page 5 of 5 ArcelorMittal Nippon Steel India Limited AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FLC013787 Request for Quotation Number 6000114308 Date 06.06.2024 Submission Date 15.06.2024 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. Chaitali Panchal Contact Email CHAITALI.PANCHAL@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 4 28035998 0004 0004 300386715 RELAY,P/N:SR71,F/A.C CIRCUIT BRAKER Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 5 NO RELAY PART NO : SR71 , MAJOR EQUIPMENT : A.C CIRCUIT BRAKER MAJOR EQUIPMENT MODEL : CN-CS , MAJOR EQUIPMENT MAKE : L AND T ADDITIONAL INFORMATION : MICROPROCESSOR BASED RELAY FOR 800/1250/1600 AMP ACB Item Details : Item Note : 5 28035998 0005 0005 300442098 METER,P/N:EM6436,F/VFD&LT PANEL Technical Details Name : Kannappa Rayappa Contact : Email : kannappa.rayappa@amns.in 20 NO ASSY/PARTS ITEM NAME : METER , PART NO : EM6436 MAJOR EQUIPMENT : ABB VFD AND LT PANEL MAJOR EQUIPMENT MODEL : YN3A210354 , MAJOR EQUIPMENT MAKE : ABB Item Details : WITH RS485 Item Note :