400Kv Gis For Powergrid Ss83t Tender Pre Bid Tie Up For Supply And Services Of 400Kv Gis And Associated Equipments For Powergrid Substation Package Ss83t (Kandla) Tender , Supply- Gis : 400Kv, 63Ka For 1S, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 1.01-1.10): 420Kv, 3150 A, 63 Ka, Sf6 Gis Ict Feeder Bay Module For Iv Sideconnection With 765Kv Ict As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Bus Reactor Bay Module As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Coupling Transformer Feeder Bay Moduleas Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Tie Bay Module (Without Pir) As Persection-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Auxiliary Bus Module For Spare Transformer As Persection-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Auxiliary Bus Module For Spare Coupling Transformer As Per Section-Project, Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Barmodule As Per Section-Project,Technical Specification , 420Kv, 3000A, 63Ka, Single Phase, Sf6gas Insulated Bus Duct (Gib) Outsidegis Hall Alongwith Associated Supportstructure , 3150A, 63Ka, 1Sec Single Phase 420Kv Sf6 To Air Bushing , Controlled Switching Device For 420 Kv, 3-Ph Circuit Breaker , Supply- Gis : Special Tools And Testing & Maintenance Instruments As Per Ts (Item Sl. No. 2.01-2.10): Sf6 Gas Processing Unit For 400Kv Gis Station , Scissor Lift , Spares- Gis : 400Kv, 63Ka For 1S, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 3.01-3.52): 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch/Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets,‚¬Å’Oã‚‚¬ÂRingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags (5 % Of Totalweight) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas (5 % Of Total Gas Quantity) , Locking Device To Keep The Dis-Connectors (Isolators)And Earthing/Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators (Gas Through) Of Each Type (Complete Withmetal Ring Etc.) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type (Complete With Metal Ring Etc.)Along With Associated Contacts And Shields , 400Kv Gis- 3150A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors,Push Buttons, Switches,Lamps,Annunciation Windows, Mcb, Fuses,Timers, Terminal Blocks Etc. Of Eachtype & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir Withinterrupter, Main Circuit, Enclosure And Operating Mechanism Completein All Respect , 400Kv Gis-One Pole Of 3150A Circuit Breaker With Pir With Interrupter,Main Circuit, Enclosure And Operating Mechanism Complete In Allrespect , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker (Asapplicable) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. (Asapplicable) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor (For Hydraulic Operated Mechanism, If Applicable) , Hydraulic Filter Of Each Type (For Hydraulic Operated Mechanism, Ifpplicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type (As Applicable) (Forhydraulic Operated Mechanism, If Applicable) , 400Kv Gis Circuit Breaker - N2 Accumulator (For Hydraulic Operatedmechanism, If Applicable) , Valves Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pipe Length (Copper & Steel) Of Each Size & Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type (For Hydraulicoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil (5% Of Total Oil Quantity)(For Hydraulic Operated Mechanism, If Applicable) , Pressure Relief Device Of Each Type (For Hydraulic Operated Mechanism,If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. (For Spring Operated Mechanism, Ifapplicable) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. (For Hydraulic-Springoperated Mechanism, If Applicable) , Pressure Switches Of Each Type For420kv Giscircuit Breaker (Forhydraulic-Spring Operated Mechanism, Ifapplicable) , Pressure Gauge With Coupling Device Of Each Type (For Hydraulic-Springoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 3150Adisconnector Switch Including Maincircuit, Enclosure, Driving Mechanismand Support Insulator Etc., Complete Inall Respect , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc.,Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit,Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch (If Applicable)-400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer (3 Cores, Type-Cta)With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Of Current Transformer (2 Cores, Type-Ctb)With Associated Enclosure And Primary Conductor Complete In Allrespect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In Allrespect , Spares- Gis: Reference Unit Price For Addition / Deletion Of Supply Items (Unit Prices Of Individual Equipment Included Here Or In Manadatory Spares Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Bidder To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (Item Sl. No. 4.01-4.02): Supply- Gis: Spares: 400Kv, Expansion Joints , Supply- Gis: Spares: 400Kv, L-Bend , Services- Gis : 400Kv, 63Ka For 1S, Gas Insulated Switchgear (Gis) As Per Ts (Item Sl. No. 5.01-5.10): Services- 400Kv Gis: Supervision Of Erection Of Gis , Services- 400Kv Gis: Supervision Of Erection Of 1- Phase Gas Insulated Bus Duct , Services- 400Kv Gis: Supervision Of Erection Of 1 Phase Sf6 To Air Bushing , Services- 400Kv Gis: Testing & Commissioning Of Gis , Services- 400Kv Gis : Testing & Commissioning Of Gas Insulated Bus Duct , Services- 400Kv Gis : Testing & Commissioning Of 1 Phase Sf6 To Air Bushing , Services- 400Kv Gis : Final Successful Hv/ Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- 400Kv Gis : Insulation Co-Ordination Studies For Gis System , Services- 400Kv Gis : Training For Gis At Site , Services- 400Kv Gis : Training For Gis At Manufacturer Works , Services- Gis : Reference Unit Price For Addition / Deletion Of Services: (Unit Prices Of Individual Services Included Here Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Vendor To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (Item Sl .No. 6.01-6.05): Services- 400Kv Gis: Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Supervision Of Erection Of Gis , Services- 400Kv Gis: Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Testing & Commissioning Of Gis , Services- 400Kv Gis: Demobilization And Remobilization Charges For Gis Erection Supervision Team , Services- 400Kv Gis: Demobilization And Remobilization Charges For Gis Testing & Commissioning Team , Services- 400Kv Gis: Demobilization & Remobilization Charges Of Hv Test Kit Along With Operator