Supply Of Laboratory Items ( Part 6 ) - 52 Single Blood Bags Cpda 350Ml:Bio Compatibility Of The Plastic Container Must Be Certified By The Manufacturer And Supported By Test Reports Of The Following Cell Culture Cytotoxicity, Haemolysis, Systemic Injection, Sensitisation, Intracutaneous Injection.Stability Studies Data To Prove 3 Years Shelf Life Shouldbe Produced.Ce Mark And Iso 9002 Quality System Certification.Conformity To Iso 3826 International Product Std.For Blood Bags.In_House R&D Center Recognised By The Govt. Of India.Marketstanding Of 5Yrs .Air Content:Container Should Not Exceed10ml.External Sterility Of The Blood Bags Must Be Assured.The Firm Must Submit Published Materials In The Scientific Journals In Favours Of The Quality Of Blood Bags. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. 53 Double Blood Bag Cpda 350: Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot. 54 Double Blood Bag Cpda 450 : Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor. 55 Triple Blood Bag Cpd With Sagm 450 : Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor. 56 Triple Blood Bag Cpda Without Sagm 350: Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot. 79 Apheresis Hydroxy Ethyl Starch 6% In Isotonic Sodium Chloride Intravenous Infusion 500 Ml 80 Apheresis Single Donor Plasma Kit ( Haemanetics ) Mcs+ 81 Apheresis Therapeutic Plasma Exchange Kit ( Haemanetics ) Mcs+ 82 Biological Indicator For Autoclave Made Up Of An External Plastic Tube With A Perforated Cap Which Made It Available For The Gaseous Interchange Contains Inside Inoculated Spore In A Filter Paper Strip & An Ampoule With An Adequate Culture Medium & A Ph Indicator Prepared For The O.E.& Steam Sterilization Process And Allows An Exactly Biological Controll With Results In A Maximum Period Of 48 Hrs 83 Blood Transfusion Set Sterilized 84 Coombs Controll Cells A Panel Of 3% Reagent Red Cells For Quality Controll Of Anti Human Globulin Procedure, Pack Size. Should Be Of 2 Ml Each, Company Should Provide Qc Report With Each Vial Supplied, Iso 13585 85 Gel Card Matrix Abd Forward And Reverse Grouping Card With Auto Controll 24 Card 86 Gel Card Matrix Abo Forward Group Card 87 Gel Card Matrix Abo Reserve Grouping & Card 24 Card 88 Gel Card Matrix Ahg Crossmatch Card 24 Card 89 Gel Card Matrix Diluent 2 ( Liss ) 250 Mlp 90 Gel Card Matrix Grouping & Confirmation Card 24 Card 91 Gel Card Matrix Neonete Grouping Card24 Card 92 Microcuvette For Hemocue Donor Hb Checker System ( Model Hemocue Hb 301 ) 93 Platelet Agitator Graph ( Penpol ) 7Days 0 / 40 94 Platelet Agitator Graph ( Remi ) Part No. 4W32 10 95 Appropriateely Diluted Monoclonal Anti D Igg And Red Cell Preserving Solution Starter Pack For Preparation Of Coombs Controll Cells In Situ, Pack Size. Should Be 10 Ml, Should Have Long Expiry, Company Should Provide Qc Report With Each Vial Supplied, Iso 13585 96 Bio Tips ( Microtips ) , 002-100Microliter, Neutral Color 97 Bio Tips ( Microtips ) , 002-100Microliter, Yellow Color 98 Bio Tips ( Microtips ) , 002-200Microliter, Neutral Color 99 Bio Tips ( Microtips ) , 002-200Microliter, Yellow Color 100 Calibrator For 3-Part Cell-Counter ( Usable For Sysmex Kx 21 ) 101 Glass Microscopic Slides Belgium Thickness 1 To 1.3Mm X75mm×25Mm Pkt. Of 50 Slides / Box 102 Brush For Test Tube Cleaning ( Nylon ) 103 Micropipette Variable Volume, Single Channel, 000.5-0050Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 104 Micropipette Variable Volume, Single Channel, 0002-0010Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 105 Micropipette Variable Volume, Single Channel, 0002-0020Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 117 Apheresis Acd Anticoagulant Solution ( 500 Ml ) , Iso 3826 Certified. 118 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 0.6 Liters. 119 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 1.8 Liters. 120 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 5.0 Liters.

Tender Notice

8965361

Indian


Gujarat

February 15, 2016

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Supply Of Laboratory Items ( Part 6 ) - 52 Single Blood Bags Cpda 350Ml:Bio Compatibility Of The Plastic Container Must Be Certified By The Manufacturer And Supported By Test Reports Of The Following Cell Culture Cytotoxicity, Haemolysis, Systemic Injection, Sensitisation, Intracutaneous Injection.Stability Studies Data To Prove 3 Years Shelf Life Shouldbe Produced.Ce Mark And Iso 9002 Quality System Certification.Conformity To Iso 3826 International Product Std.For Blood Bags.In_House R&D Center Recognised By The Govt. Of India.Marketstanding Of 5Yrs .Air Content:Container Should Not Exceed10ml.External Sterility Of The Blood Bags Must Be Assured.The Firm Must Submit Published Materials In The Scientific Journals In Favours Of The Quality Of Blood Bags. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. 53 Double Blood Bag Cpda 350: Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot. 54 Double Blood Bag Cpda 450 : Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification. Conformity To Iso 3826 International Product Standard For Blood Bags. Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time. Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds. Markings In The Tubing: Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable Without Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor. 55 Triple Blood Bag Cpd With Sagm 450 : Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Comply To I.P. Must Produce Qc Pass Certificate With Each Lot. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor. 56 Triple Blood Bag Cpda Without Sagm 350: Ce Mark, Iso 9001 2000, Directive 93 / 42 / Eec, Iso 13485:1996 Quality System Certification .Conformity To Iso 3826 International Product Standard For Blood Bags.Needle Should Generate Less Than 17 Gm Force Of Resistance Thus Ensuring Virtually Painless Venepuncture Every Time, Blood Bags Should Be Welded With High Frequency Sealing Technology Which Ensures That Bags Do Not Break Even When Centrifuged At High Speeds.Markings In The Tubing : Segment Numbering Through Thermic Technology And Numbers Should Be Very Clear, Legible And Readable With Out Any Strains To Eyes. Should Have Needle Injury Protector, Predonation Sampling Bag & Leur Adaptor.Must Produce Qc Pass Certificate With Each Lot. 79 Apheresis Hydroxy Ethyl Starch 6% In Isotonic Sodium Chloride Intravenous Infusion 500 Ml 80 Apheresis Single Donor Plasma Kit ( Haemanetics ) Mcs+ 81 Apheresis Therapeutic Plasma Exchange Kit ( Haemanetics ) Mcs+ 82 Biological Indicator For Autoclave Made Up Of An External Plastic Tube With A Perforated Cap Which Made It Available For The Gaseous Interchange Contains Inside Inoculated Spore In A Filter Paper Strip & An Ampoule With An Adequate Culture Medium & A Ph Indicator Prepared For The O.E.& Steam Sterilization Process And Allows An Exactly Biological Controll With Results In A Maximum Period Of 48 Hrs 83 Blood Transfusion Set Sterilized 84 Coombs Controll Cells A Panel Of 3% Reagent Red Cells For Quality Controll Of Anti Human Globulin Procedure, Pack Size. Should Be Of 2 Ml Each, Company Should Provide Qc Report With Each Vial Supplied, Iso 13585 85 Gel Card Matrix Abd Forward And Reverse Grouping Card With Auto Controll 24 Card 86 Gel Card Matrix Abo Forward Group Card 87 Gel Card Matrix Abo Reserve Grouping & Card 24 Card 88 Gel Card Matrix Ahg Crossmatch Card 24 Card 89 Gel Card Matrix Diluent 2 ( Liss ) 250 Mlp 90 Gel Card Matrix Grouping & Confirmation Card 24 Card 91 Gel Card Matrix Neonete Grouping Card24 Card 92 Microcuvette For Hemocue Donor Hb Checker System ( Model Hemocue Hb 301 ) 93 Platelet Agitator Graph ( Penpol ) 7Days 0 / 40 94 Platelet Agitator Graph ( Remi ) Part No. 4W32 10 95 Appropriateely Diluted Monoclonal Anti D Igg And Red Cell Preserving Solution Starter Pack For Preparation Of Coombs Controll Cells In Situ, Pack Size. Should Be 10 Ml, Should Have Long Expiry, Company Should Provide Qc Report With Each Vial Supplied, Iso 13585 96 Bio Tips ( Microtips ) , 002-100Microliter, Neutral Color 97 Bio Tips ( Microtips ) , 002-100Microliter, Yellow Color 98 Bio Tips ( Microtips ) , 002-200Microliter, Neutral Color 99 Bio Tips ( Microtips ) , 002-200Microliter, Yellow Color 100 Calibrator For 3-Part Cell-Counter ( Usable For Sysmex Kx 21 ) 101 Glass Microscopic Slides Belgium Thickness 1 To 1.3Mm X75mm×25Mm Pkt. Of 50 Slides / Box 102 Brush For Test Tube Cleaning ( Nylon ) 103 Micropipette Variable Volume, Single Channel, 000.5-0050Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 104 Micropipette Variable Volume, Single Channel, 0002-0010Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 105 Micropipette Variable Volume, Single Channel, 0002-0020Microlitre•Fully Autoclavable•Light Weight & Ergonomics Design For User Comfort•No Sharp Edges To Tear Gloves•Soft Touch Tip Ejection•Color D Volume Range For Easy Identification•Automatic Locking Of Set Volume•One Handed Operation For Safe Handling Of Potentially Infectious Materials•Super Blow Out Formicroorganisms Volume Pipetting.•Easy In Laboratory Recalibration & Maintenance.•Three Years Of Warranty 117 Apheresis Acd Anticoagulant Solution ( 500 Ml ) , Iso 3826 Certified. 118 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 0.6 Liters. 119 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 1.8 Liters. 120 Puncture Proof Container Suitable For Disposal Of Sharp Biomedical Waste And Suitable For Safe, Contamination Free Disposal Of Needle And Other Sharp Objects. Container Should Be Autoclavable At 121 Degree Celcius. Capacity : 5.0 Liters.